KILOVOLTMETER OF DIRECT AND ALTERNATING VOLTAGE LIGHTNING RD-140.
Equipment in this category:
No. |
Name | Nominal value |
1 |
DC voltage measurement range (average value), kV |
from 10 to 140 |
2 |
AC voltage measurement range (effective value), kV |
from 10 to 100 |
3 | Frequency range when measuring AC voltage, Hz | from 47.5 to 52.5 |
4 | Input resistance of the high-voltage unit MOLNIYA RD140 - BV on direct current, MOhm | 450 ± 10 |
5 | Input resistance of the high-voltage unit MOLNIA RD140 - BV on alternating current with a frequency of 50 Hz, MOhm, not less | 200 ± 5 |
6 | Limits of permissible relative error when measuring DC voltages,% | ± 1 |
7 | Limits of permissible relative error when measuring AC voltages,% | ± 1 |
8 | Readout discreteness, kV | 0.001 |
9 |
BV and MI are powered from built-in AA size Ni-MH batteries with voltage, 2V and a capacity of 1.5 A ∙ h:
|
5 ± 0.2 8 |
10 | Range of the radio channel, m, not less | five |
11 | Duration of continuous operation of LIGHTNING RD-140 at maximum input voltage, hour, no more | 1 |
12 | Duration of continuous operation of LIGHTNING RD-140 at input voltage up to 75 kV, hour, no more | 8 |
13 | Time to establish the operating mode after power-on, min., | 1 |
14 |
Overall dimensions, mm:
|
diameter 280x880 95x190x40 |
15 |
Weight, kg, no more:
|
eleven 0.5 |
16 | Service life, years, not less | ten |
Designation |
Name |
Qty. |
Note |
RD140-BV.00.00.00-02
|
High-voltage unit LIGHTNING RD140-BV |
1 |
With a power supply kit (Ni-MH rechargeable battery, size AA, 1.2 V, 1300-1800 mAh - 4 pcs.) |
RD140-MI.00.00.00
|
Indicator module LIGHTNING RD140-MI
|
1 |
With a power supply kit (Ni-MH rechargeable battery, size AA, 1.2 V, 1300-1800 mAh - 4 pcs.) |
|
Power supply stabilized
|
1 |
+ 12V stab, 0.8-1.5 A with charger splitter |
RD140-YAU.00.00.00 |
Stacking box
|
1 |
|
RD-140 / 4.00.00.00-02RE |
Passport and operation manual
|
1 |
|
Kilovoltmeter of direct and alternating voltage MOLNIYA RD-140 is intended for measuring alternating sinusoidal voltage with a frequency of 50 Hz from 10 to 100 kV and direct voltage from 10 to 140 kV.
The kilovoltmeter provides high-precision measurement:
- rms value of alternating voltage with a frequency of 50 Hz;
- average DC voltage.
The kilovoltmeter can be used in high-voltage testing laboratories of the electrical and energy industries, metrological, research and educational institutions.
The product version corresponds to GOST 17512-82, climatic category UHL 4.2 in accordance with GOST 15150-69 and group 2 of devices in accordance with GOST 22261-82.
Kilovoltmeter MOLNIYA RD-140 is designed for operation under the following conditions:
- indoors or under a canopy in the absence of shaking, vibrations, vapors of aggressive liquids;
- the distance from the high-voltage unit MOLNIYA RD140 - BV to conductive objects that are grounded or under potential is at least 1 m.
- the ripple coefficient of the measured DC voltage should be no more than 1%;
- the nonsinusoidality factor of the measured AC voltage should be no more than 8%;
- atmospheric pressure, kPa (mm Hg) - 70 - 106.7 (537-800);
- relative humidity of ambient air,% - up to 80 at 25 ° С;